| Abstract: | - Tube QA/QC Facilities Tube length measurement Wire tension measurement Leak test Wire position measurement (EMMI) End plug contact resistance measurement Dark current measurement Gregory Tarlé ATLAS UM Site Review June 1, 2000 T u T be u be Length/Wire Tension Measureme n Length/Wire Tension Measuremet n t Magnet Stop & Electrical Connection Mitoyo Linear Encoder –10 mm Electrical Connection Length Measurement Tube placed in Al angle on wiring table.
- Tension error: – 0.7 g Gregory Tarlé ATLAS UM Site Review June 1, 2000 Leak Test Tube filed with 2 atm Helium Test end plugs with He leak detector.
- Gregory Tarlé ATLAS UM Site Review June 1, 2000 Endplug Contact Resistance Measurement 1A ...
|