Skip to Contents

View Properties

Title:MiniDAQ3.0.0 User Manual
Summary:ATLAS MiniDAQ3.0.0 software using CSM0 based on VXI-VME and LabWindow
Description:CSM MiniDAQ is software developed at the University of Michigan using National Instruments LabWindows/CVI (part of Measurement Studio) for using with the CSM0 module. The purpose of the ATLAS MiniDAQ is to provide access to the CSM0 and AMT hardware in an easy way using windows interface. The ATLAS MiniDAQ has three major functions: JTAG programming, data acquisition, and hardware diagnostics.
Keywords:
Handle: Document-2073
Owner: Dai, Tiesheng (User-68, daits:DocuShare)DS
Create Date:Monday, December 22, 2003 05:42:45 PM EST
Modified Date:Monday, December 22, 2003 05:42:45 PM EST
Modified By:
Expiration Date:
Locked By:
Abstract:
  • To program an individual mezzanine card, select JTAG à Setup Individual à Mezzanine N, where N is the assigned mezzanine card ID.
  • Figure 3.
  • The Mezzanine Card Setup Window The JTAG à Setup All and JTAG à Setup Individual will bring up an AMT mezzanine card setup window shown in Figure 3 (from JTAG à Setup All), which contains switches, selection boxes and command buttons.
  • Copy Mezzanine Card Settings There is a command button in the mezzanine card setup window as shown in Figure 2.
  • It brings up the copy mezzanine card setup window as shown in Figure 6 and it allows user to copy mezzanine card settings between mezzanine cards.
  • 4.1 CSM Input Channel Control (TDC Enable and Control) To ...