Tube QA/QC Facilities Tube QA/Q

C Facilities

Tube length measurement

Wire tension measurement

Leak test

Wire position measurement (EM

MI)

End plug contact resistance m

easurement

Dark current measurement

Gregory Tarlé

A

TLAS UM Site Review June 1, 20

00

 

T

ub

e

T

ub

e

Leng

t

h

/

W

i

r

e Tens

i

o

n Measure

me

nt

Leng

t

h

/

W

i

r

e Tens

i

o

n Measure

me

nt

Magnet

Stop &

El ectrical

Connection

Mitoyo

Li near

Encoder

10 mm

Electrical

Connection

Length Measurement

Tube placed in Al angle on wir

ing table.

Tube pushed against stop.

Length measured with linear en

coder 10 m m.

Encoder read out by computer.

Wire Tension Measurement

Tube placed in Al angle on wi r

ing table.

Wire vibrations excited by inj

ecting current

pulse with tube

inside U?magnet.

Induced voltage read out with

computer

DAQ card and Fourier

analyzed to fin d

frequency. Te

nsion error:

 

 

0. 7 g

Gregory Tarlé

A

TLAS UM (

 

Leak Test Leak Test

Tube filled with 2 atm Helium

Test end plugs with He leak d

etector. Special cap tests for

leaks out end of end plug. He

l

eak det ector sensitivity < 10

?9

bar?cc/s.

Sliding fixture tests tube bo

dy with He sniffer. Fixture is

purged with Nitrogen to remove

backgro und He.

Calibration done with calibra

ted leak (10

?6

bar?c c/s) and built?in calibra

ted leak of H e

leak detector (r

epeated daily).

Endplug fixture

Sliding fixture

Helium Leak Detector

Gregory Tarlé

A

TLAS UM Site Review June 1, 20

00

 

ElectroMagnetic MIcrometer (EM

MI) ElectroMagnetic MIcromete r (

EMMI)

EMMI measures wire position w

ithin to 2 m m.

EMMI stand located on leak de

tector stand.

Both ends measured simultaneo

usly.

Tu be rotated 180ű to eliminat

e offset.

Tube rotated 90 ű fo r other vi

ew.

EMMI is li near over a wide ra

nge (> 300 mm).

Measurement takes 2 minutes.

Gregory Tarlé

A

TLAS UM Site Review June 1, 20

00

 

Endplug Contact Resistance Mea

surement Endplug Contact Resista

nce Measurement

1A current passed between en d

plug and tube.

Voltage drop across end plug

measured with multimeter.

In future, resistance measure

ment will be incorporated in

 

 

EMMI stand with computer read

out using DAQ card.

Gregory Tarlé

A

TLAS UM Site Review June 1, 20

00

 

Dark Current Measurement Dark C

urrent Measurement

Facility handles 1 day’s prod

uction of tubes (48).

Gas jumpers and HV distributi

on cards connected to tubes.

Ar/CO

2

93:7 @3atm.

Tubes with high initial dark

current are treated with revers

e HV.

Computer monitoring of dark cu

rrent overnight.

Gregory Tarlé

A

TLAS UM Site Review June 1, 20

00

Back to top